LifeTech Scientific CERA PDA Occluder

LifeTech Scientific CERA PDA Occluder

The CeraTM Occluder series has been demonstrated its benefits in design
and material, proven its efficacy and safety in congenital and structural
heart disease treatment with over 50,000 occluders implanted.
BENEFITS
Excellent Long-term Benefit -Proprietary Titanium Nitride (TiN) Coating
Decrease the metallic ion leaching .
Accelerate endothelialization, lessen thrombus complication (2)
Efficacy and Safety
Reduce vessel trauma by low profile sheath with PET Membrane securely sewn into ASD / PFO device.
Block high-pressure blood flow with PTFE Membrane securely sewn into VSD /PDA device.
Reduce atrioventricular block occurrence effectively with superior memory feature.
Precisely Matched Clinical Condition
Four types of VSD devices designed upon anatomical feature.
ASD occluder is available ranging from 6 to 42 mm, and PDA occluder ranging from 0406 to 2224.

CERA PDA Occluder
Retention Skirt – 10-30 mm
Proximal Diameter – 4- 22 mm
Distal Diameter – 6- 24 mm
Waist Length – 7-10 mm
Minimum recommended Sheath size Steer Ease (Fr); SFP6F
Minimum recommended Sheath size Steer Ease (Fr); SFP5F

0.00

Description

The CeraTM Occluder series has been demonstrated its benefits in design
and material, proven its efficacy and safety in congenital and structural
heart disease treatment with over 50,000 occluders implanted.
BENEFITS
Excellent Long-term Benefit -Proprietary Titanium Nitride (TiN) Coating
Decrease the metallic ion leaching .
Accelerate endothelialization, lessen thrombus complication (2)
Efficacy and Safety
Reduce vessel trauma by low profile sheath with PET Membrane securely sewn into ASD / PFO device.
Block high-pressure blood flow with PTFE Membrane securely sewn into VSD /PDA device.
Reduce atrioventricular block occurrence effectively with superior memory feature.
Precisely Matched Clinical Condition
Four types of VSD devices designed upon anatomical feature.
ASD occluder is available ranging from 6 to 42 mm, and PDA occluder ranging from 0406 to 2224.

CERA PDA Occluder
Retention Skirt – 10-30 mm
Proximal Diameter – 4- 22 mm
Distal Diameter – 6- 24 mm
Waist Length – 7-10 mm
Minimum recommended Sheath size Steer Ease (Fr); SFP6F
Minimum recommended Sheath size Steer Ease (Fr); SFP5F

Additional information

Model

Cera Muscular VSD, Cera Membranous VSD (Symmetric)

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.