Henry Schien ACTEON X-Mind Prime 3D Cone-beam computed tomography systems (CBCT)

Henry Schien ACTEON X-Mind Prime 3D Cone-beam computed tomography systems (CBCT)

Henry Schien ACTEON X-Mind Prime 3D Cone-beam computed tomography systems (CBCT)

ACTEON X-Mind Prime 3D Cone-beam computed tomography systems (CBCT)
IT’S TIME FOR EFFICIENT 3D & PANORAMIC IMAGING
3D Diagnosis is more accessible than ever with a smart and compact solution. X-Mind Prime is a smart solution, providing high-technology capabilities and simplicity of use. This ingenious unit offers all essential diagnostic tools in a cost effective package:
• 1 to 1 Face-to-face patient positioning
• 1minute to edit your implant report with the intuitive AIS software
• 0 Footprint space with the innovative wall mounted system
• 100% Mac® and Windows® compatible with AIS software
X-Mind® prime is a complete imaging solution combining panoramic and 3D X-rays, from general examination to specific treatment planning. Choose your 2D and 3D examination from a wide range of clinical applications, plan your treatment and efficiently communicate with your patient.
RELY ON A COMPLETE SET OF PANORAMIC EXAMS
Panoramic
• Standard
• Half Panoramic (right/left)
• Frontal Dentition
• Low Dose
• Ortho Rad
Bitewing
• Single (right/left)
• Bilateral
Sinus
TMJ
• Standard
• Single phase
X-Mind® prime 3D offers a multitude of acquisition programs thanks to its multiple FOV (50x50mm, 85x50mm, and 85x93mm). Once you select the region of interest of the examination, the settings and dose are automatically adjusted.
SEVERAL FOV’s FOR MANY APPLICATIONS:
Full dentition
Single jaw (maxillary / mandibular)
Maxillary teeth
• (right molars/right premolars/incisor/left Molars/left premolars)
Mandibular teeth
• (right molars/right premolars/incisor/Left molars/left premolars)
TMJ (right/left)
Sinus
X-Mind® prime’s dedicated holder allows for scans of 3D models in various materials and designs (impressions, stone models, appliances, etc.). Easily export data in STL format!
To maximize productivity, X-Mind® prime is specifically designed to reduce the patient preparation time. Natural face-to-face positioning supported by alignment lasers for correct patient positioning. Whether sitting or standing at any height, the telescopic columns can be directly adjusted using the control panel. X-Mind prime’s open space configuration suits all types of patients and is easily accessible for wheelchair users with its zero footprint space.
ADVANCED FUNCTIONALITY FOR INTUITIVE NAVIGATION
AIS software allows you to manage panoramic and CBCT images from acquisition to viewing:
• Implant planning
• Crown placement
• Mandibular nerve tracing
• Easy navigation in different sections
• Surface, distance and angle measurement
• Substantial and scalable implant library
• Printed implant report
• Sharing of information on a network
• Cases exported on a CD or USB stick
• Export in STL format
• Metal artifact reduction filter
• Panoramic and cephalometric image detail optimization filter
• ENT module
• Virtual endoscope
• Integrates with various patient management software
• DICOM compatible
X-Mind® prime is ready to install! Delivered completely assembled at your practice, you are all set-up in only one hour. As simple as one box, one technician, two steps and that’s it! It does not interrupt the daily work and operations of the office, helping you to save time.
X-Mind® prime 2D:
X-RAY SOURCES
Tube type: D-058 (Toshiba)
Total filtration: 2.0 mm AI eq. @ 70kVp
Tube voltage: 60 – 70 kV
Anodic current: 2-7.1 mA
Focal spot: 0.5 mm
SENSOR
Type: CCD
Pixel size: 48 μm
ACQUISITION
PAN Programs: Panoramic (adult/child) – TMJ open/closed mouth in lateral projection – Maxillary sinuses (P-A) – Half panoramic (left/right). Low dose panoramic – Frontal dentition – Ortho Rad Panoramic – Bitewing (left/right/double)
Exposure time: up to 14.4 sec
Grey levels: 4096 – 12 bits
MECHANICAL DATA
Footprint: 43.6’’ x 37.5’’
Height: Max 86.2 inches
Weight: 137 lbs
IEC
Class & Type: Class I with type B applied parts according to IEC 60601-1 classification. X-Mind® prime is manufactured by Villa Sistemi Medicali and distributed by ACTEON.
WORKSTATION MINIMUM REQUIREMENTS
PAN/CEPH WINDOWS (WORKSTATION):
Processor: Intel i5
Hard Disk: 1TB 7200 rpm
RAM: 8 GB
Graphics card: OPEN GL 2.1 compatible (suggested an NVIDIA GT/GTX)
Screen resolution: 1600 x 1024
Network card: INTEL CT 1000 pro
Operating system: Windows 7 Professional 64 bits
CLIENT WINDOWS:
Processor: Intel i5
Hard Disk: 300 GB
RAM: 4 GB or 8 GB (for big FOV DICOM stacks)
Graphics card: Nvidia Geforce or Nvidia Quadro with 1 GB dedicated RAM
Screen resolution: 1600 x 1024
Network card: 100 Mb for PAN/CEPH
Operating system: Windows 7 64 bits
CLIENT MAC OS
Processor: Quadcore 2.6 GHz
Hard Disk: 300 GB
RAM: 4 GB or 8 GB (for big FOV DICOM stacks)
Graphics card: Nvidia Geforce or Nvidia Quadro with 1 GB dedicated RAM
Screen resolution: 1600 x 1024
Network card: 100 Mb for PAN/CEPH
Operating system: OS X Sierra (10.12)
X-Mind® prime 3D:
X-RAY SOURCES
Tube type: OPX 105-12 (CEI)
Total filtration: ≥ 2.5 mm AI eq. @ 86 kVp
Tube voltage: 60 – 86 kV
Anodic current: 2-12.5 mA
Focal spot: 0.5 mm
SENSOR
Type: CMOS Flat panel
Pixel size: 120 μm
Voxel size: Minimum 87.5 μm
ACQUISITION
PAN Programs: Panoramic (adult/child) – TMJ open/closed mouth in lateral projection – Maxillary sinuses (P-A) – Half panoramic (left/right). Low dose panoramic – Frontal dentition – Ortho Rad Panoramic – Bitewing (left/right/double)
3D Programs: Full dentition (85 x 93 mm)* – Single jaw (85 x 50 mm)* – Mandibular teeth (50 x 50 mm) – Maxillary teeth (50 x 50 mm) – TMJ (85 x 93 mm)* – Sinus (85 x 93 mm)*
Exposure time: 7 s. (full dentition)
Grey levels: 65536 – 16 bits
MECHANICAL DATA
Footprint: 43.6’’ x 37.5’’
Height: Max 86.2 inches
Weight: 148 lbs
IEC
Class & Type: Class I with type B applied parts according to IEC 60601-1 classification
X-Mind® prime is manufactured by Villa Sistemi Medicali and distributed by ACTEON.
WORKSTATION MINIMUM REQUIREMENTS
PAN/CEPH WINDOWS (WORKSTATION):
Processor: Intel i5
Hard Disk: 1TB 7200 rpm
RAM: 8 GB
Graphics card: OPEN GL 2.1 compatible (suggested an NVIDIA GT/GTX)
Screen resolution: 1600 x 1024
Network card: INTEL CT 1000 pro
Operating system: Windows 7 Professional 64 bits
CLIENT WINDOWS:
Processor: Intel i5
Hard Disk: 300 GB
RAM: 4 GB or 8 GB (for big FOV DICOM stacks)
Graphics card: Nvidia Geforce or Nvidia Quadro with 1 GB dedicated RAM
Screen resolution: 1600 x 1024
Network card: 100 Mb for PAN/CEPH
Operating system: Windows 7 64 bits
CLIENT MAC OS
Processor: Quadcore 2.6 GHz
Hard Disk: 300 GB
RAM: 4 GB or 8 GB (for big FOV DICOM stacks)
Graphics card: Nvidia Geforce or Nvidia Quadro with 1 GB dedicated RAM
Screen resolution: 1600 x 1024
Network card: 100 Mb for PAN/CEPH
Operating system: OS X Sierra (10.12)

0.00

Description

ACTEON X-Mind Prime 3D Cone-beam computed tomography systems (CBCT)
IT’S TIME FOR EFFICIENT 3D & PANORAMIC IMAGING
3D Diagnosis is more accessible than ever with a smart and compact solution. X-Mind Prime is a smart solution, providing high-technology capabilities and simplicity of use. This ingenious unit offers all essential diagnostic tools in a cost effective package:
• 1 to 1 Face-to-face patient positioning
• 1minute to edit your implant report with the intuitive AIS software
• 0 Footprint space with the innovative wall mounted system
• 100% Mac® and Windows® compatible with AIS software
X-Mind® prime is a complete imaging solution combining panoramic and 3D X-rays, from general examination to specific treatment planning. Choose your 2D and 3D examination from a wide range of clinical applications, plan your treatment and efficiently communicate with your patient.
RELY ON A COMPLETE SET OF PANORAMIC EXAMS
Panoramic
• Standard
• Half Panoramic (right/left)
• Frontal Dentition
• Low Dose
• Ortho Rad
Bitewing
• Single (right/left)
• Bilateral
Sinus
TMJ
• Standard
• Single phase
X-Mind® prime 3D offers a multitude of acquisition programs thanks to its multiple FOV (50x50mm, 85x50mm, and 85x93mm). Once you select the region of interest of the examination, the settings and dose are automatically adjusted.
SEVERAL FOV’s FOR MANY APPLICATIONS:
Full dentition
Single jaw (maxillary / mandibular)
Maxillary teeth
• (right molars/right premolars/incisor/left Molars/left premolars)
Mandibular teeth
• (right molars/right premolars/incisor/Left molars/left premolars)
TMJ (right/left)
Sinus
X-Mind® prime’s dedicated holder allows for scans of 3D models in various materials and designs (impressions, stone models, appliances, etc.). Easily export data in STL format!
To maximize productivity, X-Mind® prime is specifically designed to reduce the patient preparation time. Natural face-to-face positioning supported by alignment lasers for correct patient positioning. Whether sitting or standing at any height, the telescopic columns can be directly adjusted using the control panel. X-Mind prime’s open space configuration suits all types of patients and is easily accessible for wheelchair users with its zero footprint space.
ADVANCED FUNCTIONALITY FOR INTUITIVE NAVIGATION
AIS software allows you to manage panoramic and CBCT images from acquisition to viewing:
• Implant planning
• Crown placement
• Mandibular nerve tracing
• Easy navigation in different sections
• Surface, distance and angle measurement
• Substantial and scalable implant library
• Printed implant report
• Sharing of information on a network
• Cases exported on a CD or USB stick
• Export in STL format
• Metal artifact reduction filter
• Panoramic and cephalometric image detail optimization filter
• ENT module
• Virtual endoscope
• Integrates with various patient management software
• DICOM compatible
X-Mind® prime is ready to install! Delivered completely assembled at your practice, you are all set-up in only one hour. As simple as one box, one technician, two steps and that’s it! It does not interrupt the daily work and operations of the office, helping you to save time.
X-Mind® prime 2D:
X-RAY SOURCES
Tube type: D-058 (Toshiba)
Total filtration: 2.0 mm AI eq. @ 70kVp
Tube voltage: 60 – 70 kV
Anodic current: 2-7.1 mA
Focal spot: 0.5 mm
SENSOR
Type: CCD
Pixel size: 48 μm
ACQUISITION
PAN Programs: Panoramic (adult/child) – TMJ open/closed mouth in lateral projection – Maxillary sinuses (P-A) – Half panoramic (left/right). Low dose panoramic – Frontal dentition – Ortho Rad Panoramic – Bitewing (left/right/double)
Exposure time: up to 14.4 sec
Grey levels: 4096 – 12 bits
MECHANICAL DATA
Footprint: 43.6’’ x 37.5’’
Height: Max 86.2 inches
Weight: 137 lbs
IEC
Class & Type: Class I with type B applied parts according to IEC 60601-1 classification. X-Mind® prime is manufactured by Villa Sistemi Medicali and distributed by ACTEON.
WORKSTATION MINIMUM REQUIREMENTS
PAN/CEPH WINDOWS (WORKSTATION):
Processor: Intel i5
Hard Disk: 1TB 7200 rpm
RAM: 8 GB
Graphics card: OPEN GL 2.1 compatible (suggested an NVIDIA GT/GTX)
Screen resolution: 1600 x 1024
Network card: INTEL CT 1000 pro
Operating system: Windows 7 Professional 64 bits
CLIENT WINDOWS:
Processor: Intel i5
Hard Disk: 300 GB
RAM: 4 GB or 8 GB (for big FOV DICOM stacks)
Graphics card: Nvidia Geforce or Nvidia Quadro with 1 GB dedicated RAM
Screen resolution: 1600 x 1024
Network card: 100 Mb for PAN/CEPH
Operating system: Windows 7 64 bits
CLIENT MAC OS
Processor: Quadcore 2.6 GHz
Hard Disk: 300 GB
RAM: 4 GB or 8 GB (for big FOV DICOM stacks)
Graphics card: Nvidia Geforce or Nvidia Quadro with 1 GB dedicated RAM
Screen resolution: 1600 x 1024
Network card: 100 Mb for PAN/CEPH
Operating system: OS X Sierra (10.12)
X-Mind® prime 3D:
X-RAY SOURCES
Tube type: OPX 105-12 (CEI)
Total filtration: ≥ 2.5 mm AI eq. @ 86 kVp
Tube voltage: 60 – 86 kV
Anodic current: 2-12.5 mA
Focal spot: 0.5 mm
SENSOR
Type: CMOS Flat panel
Pixel size: 120 μm
Voxel size: Minimum 87.5 μm
ACQUISITION
PAN Programs: Panoramic (adult/child) – TMJ open/closed mouth in lateral projection – Maxillary sinuses (P-A) – Half panoramic (left/right). Low dose panoramic – Frontal dentition – Ortho Rad Panoramic – Bitewing (left/right/double)
3D Programs: Full dentition (85 x 93 mm)* – Single jaw (85 x 50 mm)* – Mandibular teeth (50 x 50 mm) – Maxillary teeth (50 x 50 mm) – TMJ (85 x 93 mm)* – Sinus (85 x 93 mm)*
Exposure time: 7 s. (full dentition)
Grey levels: 65536 – 16 bits
MECHANICAL DATA
Footprint: 43.6’’ x 37.5’’
Height: Max 86.2 inches
Weight: 148 lbs
IEC
Class & Type: Class I with type B applied parts according to IEC 60601-1 classification
X-Mind® prime is manufactured by Villa Sistemi Medicali and distributed by ACTEON.
WORKSTATION MINIMUM REQUIREMENTS
PAN/CEPH WINDOWS (WORKSTATION):
Processor: Intel i5
Hard Disk: 1TB 7200 rpm
RAM: 8 GB
Graphics card: OPEN GL 2.1 compatible (suggested an NVIDIA GT/GTX)
Screen resolution: 1600 x 1024
Network card: INTEL CT 1000 pro
Operating system: Windows 7 Professional 64 bits
CLIENT WINDOWS:
Processor: Intel i5
Hard Disk: 300 GB
RAM: 4 GB or 8 GB (for big FOV DICOM stacks)
Graphics card: Nvidia Geforce or Nvidia Quadro with 1 GB dedicated RAM
Screen resolution: 1600 x 1024
Network card: 100 Mb for PAN/CEPH
Operating system: Windows 7 64 bits
CLIENT MAC OS
Processor: Quadcore 2.6 GHz
Hard Disk: 300 GB
RAM: 4 GB or 8 GB (for big FOV DICOM stacks)
Graphics card: Nvidia Geforce or Nvidia Quadro with 1 GB dedicated RAM
Screen resolution: 1600 x 1024
Network card: 100 Mb for PAN/CEPH
Operating system: OS X Sierra (10.12)