Henry Schien Air Techniques ProVecta HD Intraoral X-Ray

Henry Schien Air Techniques ProVecta HD Intraoral X-Ray

Henry Schien Air Techniques ProVecta HD Intraoral X-Ray

Air Techniques ProVecta HD Intraoral X-Ray
ProVecta HD Intraoral X-Ray: Perfect in Function & Design.
  • DC tube features a 0.4 mm focal point for maximum image sharpness
  • The smaller the focal spot, the greater the contrast resolution, which provides sharper edge definition and finer details of internal structures
  • ProVecta HD works with wired sensors, cordless flexible phosphor sensors (PSPs) and film
  • Generator head handle allows precise positioning that stays in place
  • Right-angle/parallel technology for precise alignment
  • Adjustable mA and kV and exposure time
  • Optional rectangular radiation field collimator
  • DC technology allows constant radiation levels to ensure reliable image quality
  • Our special generator head handle not only allows precise positioning, it makes the process more comfortable for both the clinician and the patient
  • Choose from 3 Extended arm lengths: short (68″), medium (74″), and long (86″)
  • The DC tube reduces the patient radiation dose by more than 25% in comparison to conventional AC units, ensuring greater safety for your patients and staff
  • This state-of-the-art unit’s small footprint, coupled with its right-angle/parallel technology, allows it to work its magic in less space than less-advanced units
  • Factory programmed dosage specifically set for each view of teeth when using ScanX flexible phosphor sensors (PSP).
Power input
 AC 100-240 V +/- 10 %, 50/60 Hz
Power rating (W)
 500
Tube voltage (kVp)
 60 – 70
Tube current (mA)
 4 – 7
Tube length (in)
 8“ (12“ optional)
Radiation field limits (in)
 2.4“/1.2“ x 1.6“ (0.8“ x 1.2“ optional)
Exposure time (sec.)
0.04 – 2
Focal spot size (mm)
0.4 (IEC 60336)
Total filtration (mm)
Min. 2.0 Al
Weight (lbs)
55/56/59 lbs (short/medium/long arm)
Storage height (in)
45“
Extended arm length (in)
74“ (68“ and 86“ optional)

0.00

Description

Air Techniques ProVecta HD Intraoral X-Ray
ProVecta HD Intraoral X-Ray: Perfect in Function & Design.
  • DC tube features a 0.4 mm focal point for maximum image sharpness
  • The smaller the focal spot, the greater the contrast resolution, which provides sharper edge definition and finer details of internal structures
  • ProVecta HD works with wired sensors, cordless flexible phosphor sensors (PSPs) and film
  • Generator head handle allows precise positioning that stays in place
  • Right-angle/parallel technology for precise alignment
  • Adjustable mA and kV and exposure time
  • Optional rectangular radiation field collimator
  • DC technology allows constant radiation levels to ensure reliable image quality
  • Our special generator head handle not only allows precise positioning, it makes the process more comfortable for both the clinician and the patient
  • Choose from 3 Extended arm lengths: short (68″), medium (74″), and long (86″)
  • The DC tube reduces the patient radiation dose by more than 25% in comparison to conventional AC units, ensuring greater safety for your patients and staff
  • This state-of-the-art unit’s small footprint, coupled with its right-angle/parallel technology, allows it to work its magic in less space than less-advanced units
  • Factory programmed dosage specifically set for each view of teeth when using ScanX flexible phosphor sensors (PSP).
Power input
 AC 100-240 V +/- 10 %, 50/60 Hz
Power rating (W)
 500
Tube voltage (kVp)
 60 – 70
Tube current (mA)
 4 – 7
Tube length (in)
 8“ (12“ optional)
Radiation field limits (in)
 2.4“/1.2“ x 1.6“ (0.8“ x 1.2“ optional)
Exposure time (sec.)
0.04 – 2
Focal spot size (mm)
0.4 (IEC 60336)
Total filtration (mm)
Min. 2.0 Al
Weight (lbs)
55/56/59 lbs (short/medium/long arm)
Storage height (in)
45“
Extended arm length (in)
74“ (68“ and 86“ optional)