Aegisy Vena Cava Filter

Aegisy Vena Cava Filter

Aegisy Vena Cava Filter

Product Introduction

Aegisy™ Vena Cava Filter is indicated for filtrating thrombus after percutaneous placement in the inferior vena cava.

◇ Precisely Controlled Release

· There is one nut (with screw) at the proximal and the distal end of the filter respectively, allowing attachment with the delivery cable

· Precise positioning, accurate deployment

· Avoid “jumping forward” when released

◇ Outstanding Filtration Capability

· Asymmetric lantern design

· A three Y-shaped caudal entry basket

· A six diamond-shaped cranial basket-filtration only at this layer

· Large capacity for clot trapping

· Transverse symmetry offers great stability of clot trapping

◇ Desirable IVC Patency Rate

· Asymmetric configuration-filtration at only one layer

· Minimize the impact on blood flow dynamics after clot capture

· Central turbulent shear force enables the blood flow to break the clot apart

· Prevent thrombus from spreading in VCF

· Maintain desirable long-term IVC patency

◇ Easy to Retrieve (as a retrievable filter)

· High success rate of retrieval

· Retrieving hook-at the end of caudal basket

· Retrieval time-up to and including 14 days

· Retrieval via the femoral vein only

◇ Safe and Reliable

· Laser cut-fatigue resistant

· Highly biocompatible

· 6F delivery system reduces vessel injury

· Six securing anchors-fix filter to vessel wall

· Six straight struts-prevent device from tilting

· Low incidence rate of migration or fracture

◇ Dual Access-Jugular or Femoral

The filter is preloaded for femoral use. Reassemble the device according to IFU before usage in jugular. The length of the introducer sheath is 55cm.

Aegisy Vena Cava Filter

Description

Product Introduction

Aegisy™ Vena Cava Filter is indicated for filtrating thrombus after percutaneous placement in the inferior vena cava.

◇ Precisely Controlled Release

· There is one nut (with screw) at the proximal and the distal end of the filter respectively, allowing attachment with the delivery cable

· Precise positioning, accurate deployment

· Avoid “jumping forward” when released

◇ Outstanding Filtration Capability

· Asymmetric lantern design

· A three Y-shaped caudal entry basket

· A six diamond-shaped cranial basket-filtration only at this layer

· Large capacity for clot trapping

· Transverse symmetry offers great stability of clot trapping

◇ Desirable IVC Patency Rate

· Asymmetric configuration-filtration at only one layer

· Minimize the impact on blood flow dynamics after clot capture

· Central turbulent shear force enables the blood flow to break the clot apart

· Prevent thrombus from spreading in VCF

· Maintain desirable long-term IVC patency

◇ Easy to Retrieve (as a retrievable filter)

· High success rate of retrieval

· Retrieving hook-at the end of caudal basket

· Retrieval time-up to and including 14 days

· Retrieval via the femoral vein only

◇ Safe and Reliable

· Laser cut-fatigue resistant

· Highly biocompatible

· 6F delivery system reduces vessel injury

· Six securing anchors-fix filter to vessel wall

· Six straight struts-prevent device from tilting

· Low incidence rate of migration or fracture

◇ Dual Access-Jugular or Femoral

The filter is preloaded for femoral use. Reassemble the device according to IFU before usage in jugular. The length of the introducer sheath is 55cm.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.