Mindray SV800 Ventilator

Mindray SV800 Ventilator

Mindray SV800 Ventilator

Technical Specification
Physical Specification
Dimensions and weight
Dimensions (HxWxD) 1425mmX530mmX647mm
(Including the trolley,including backup air supply)
936mmX473mmX298mm
(Excluding the trolley,including backup air supply))
681mmX473mmX298mm
(Excluding the trolley,excluding backup air supply)
Weight Approximately 48kg
(including the trolley,including backup air supply)
Display
Screen 18.5” Color active matrix TFT touch screen
Display Resolution (H)x(V)1920X1080 pixels
Brightness Adjustable
Trolley
Dimensions 760mm(depth)X530mm(width)X980mm(height)
Weight 17 kg
Communication interface
Communication interface RS-232, Nurse call connector, VGA connector,
USB PortX4, Ethernet
Ventilation Specifications
Patient Type Adult, Pediatric, Neonate
Ventilation Mode V-A/C (Volume assist/control)
P-A/C (Pressure assist/control)
V-SIMV (Volume-Synchronized Intermittent
Mandatory Ventilation)
P-SIMV (Pressure-Synchronized Intermittent
Mandatory Ventilation)
Duolevel (Duo Level Ventilation)
CPAP (Continuous Positive Airway Pressure)
PSV (Pressure Support Ventilation)
VS (Volume Support)
APRV (Airway Pressure Release Ventilation)
PRVC (Pressure Regulated Volume Control)
PRVC-SIMV (PRVC-Synchronized Intermittent
Mandatory Ventilation)
AMV (Adaptive Minute Ventilation)
CPRV (Cardio-Pulmonary Resuscitation
Ventilation)
PSV-S/T(Pressure Support
Ventilation-Spontaneous/Timed)
nCPAP(Nasal Continuous Positive Airway Pressure
ventilation)
Controlled Parameters
O2
% 21 to 100 vol.%
TV (Tidal Volume) Adult: 100 to 4000 mL
Pediatric: 20 to 300 mL
Neonate: 2 to 100 mL
MV% 25% to 350%
f (Ventilation frequency) Adult / Pediatric: 1 to 100 /min
Neonate: 1 to 150 /min
fsimv (Ventilation frequency in SIMV mode)
1 to 60 /min
I:E 1:10 to 4:1
Tinsp (Inspiratory time) 0.10 to 10.00 s
Tslope (Time of pressure rising)
0.00 to 2.00 s
Thigh 0.10 to 30.00 s
Tlow 0.20 to 30.00 s
Tpause OFF, 5% to 60%
Flow Adult: 6 to 180 L/min
Pediatric: 6 to 30 L/min
Neonate: 2 to 30 L/min
∆Pinsp 1 to 100 cmH2O
∆Psupp 0 to 100 cmH2O
Phigh 0 to 100 cmH2O
Plow 0 to 50 cmH2O
PEEP 0 to 50 cmH2O
Flow trigger OFF,
Adult/Pediatric: 0.5 to 20.0 L/min;
Neonate: 0.1 to 5.0 L/min
Pressure trigger OFF, -20.0 to -0.5 cmH2O
Exp% (Expiration termination level)
Auto, 5% to 85%
Base flow Automatic adjustment (3-40L/min in invasive
mode, 10-65L/min in non-invasive mode)
Neg.Plimit (in CPRV mode) -30 to 0 cmH2O
Apnea Ventilation
TVapnea Adult: 100 to 4000 mL
Pediatric: 20 to 300 mL
Neonate: 2 to 100 mL
∆Papnea 1 to 100 cmH2O
fapnea Adult / Pediatric: 1 to 100 bpm
Neonate: 1 to 150 bpm
Apnea Tinsp 0.10 to 10.00 s
Sigh
Sigh Switch ON, OFF
Interval 20 s to 180 min
Cycles Sigh 1 to 20
∆int. PEEP OFF, 1 to 40 cmH2O
Automatic Tube Resistance Compensation
Tube Type ET Tube, Trach Tube, Disable ATRC
Tube I.D. Adult: 5.0 to 12.0 mm
Pediatric: 2.5 to 8.0 mm
Neonate: 2.5 to 5.0 mm
Compensate 1 to 100 %
Expiration Compensation Switch
ON, Off
O2
Therapy
O2
% 21 to 100 vol.%
Flow Adult: 2 to 60 L/min
Pediatric: 2 to 25 L/min
Leakage Compensation
Maximum leakage compensation flow
Adult: 65L/min
Pediatric: 45L/min
Neonate: 15L/min
Monitored parameters
Airway pressure range Ppeak, Pplat, Pmean,
(Range -20 to 120 cmH₂O)
PEEP (Range 0 to 120 cmH₂O)
Tidal volume range TVi, TVe, TVe spn,(Range 0 to 6000 mL)
Frequency range ftotal, fmand, fspn, (Range 0 to 200 /min)
Minute volume range MVi, MVe, MVspn, MVleak,
(Range
Adult/Pediatric: 0 to 100 L/min
Neonate: 0 to 30 L/min)
Leak% 0 to 100%
Resistance Rinsp, Rexp, (Range 0 to 600 cmH₂O/L/s)
Compliance Cstat, Cdyn, (Range 0 to 300 mL/cmH₂O)
Inspired Oxygen (FiO2
) 15 to 100 vol.%
RSBI 0 to 9999 1/(min*L)
WOB WOBtot, WOBvent, WOBimp, WOBpat
(Range: 0 to 100 J/min)
P0.1 -20 to 0 cmH₂O
NIF -45 to 0 cmH₂O
PEEPi 0 to 120 cmH₂O
Vtrap 0 to 4000 mL
RCexp 0 to 10 s
TVe/IBW 0 to 50 mL/kg
I:E 150:1 to1:150
Tinsp 0.00 to 60.00s
PIF (peak inspiratory flow) Adult/Pediatric: 0 to 300 L/min
Neonate: 0 to 30 L/min
PEF (peak expiratory flow)Adult/Pediatric: 0 to 180 L/min
Neonate: 0 to 30 L/min
EEF (end expiratory flow) Adult/Pediatric: 0 to 180 L/min
Neonate: 0 to 30 L/min
C20/C 0.00 to 5.00
Waveforms Airway pressure-time, Flow-time, Volume-
time, CO2
-time , Pleth-time
Loops Paw-Volume, Flow-Volume, Paw-Flow,
Volume-CO2
Alarm settings
Tidal Volume High Neo: Off, 3 to 200 mL
Ped: Off, 25 to 600 mL
Adu: Off,110 to 6000 mL
Low Neo: Off, 1 to 195 mL
Ped: Off, 10 to 595 mL
Adu: Off, 50 to 5995 mL
Minute Volume High Neo: 0.02 to 30.0 L/min
(can be set to Off in nCPAP)
Ped: 0.2 to 60.0 L/min
Adu: 0.2 to 100.0 L/min
Low Neo: 0.01 to 15 L/min
Ped: 0.1 to 30.0 L/min
Adu: 0.1 to 50.0 L/min
(can be set to Off in NIV)
Airway pressure High 10 to 105 cmH2O
Low OFF, 1 to 100 cmH2O
Frequency High OFF, 2 to 160 /min
Low OFF, 1 to 159 /min
Inspired Oxygen (FiO2
) High FiO2
exceeds the alarm limit for at least
30 s, internal alarm limit: set value+max
(7 vol.% or set value X10% ) or 100 vol.%,
whichever is lower.
Low FiO2
lower than the alarm limit for at
least 30 s, internal alarm limit: set
value-max (7 vol.% or set valueX10%) or
18%, whichever is greater.
Apnea alarm time Low 5 to 60 s (can be set to Off in nCPAP)
Other Alarms Low battery voltage
Gas supply pressure low
Airway obstruction
Tube disconnected
PEEP too high
Trend
Type Tabular, Graphic
Length 96 hours
Content Monitor Parameters, Setting Parameters
(Setting Ventilation mode and Parameters)
Log
Type Alarm, Operation
Max number 5000
Screen Capture
Max number 20 pictures
Ventilator components
O2
sensor
Type Calvanic fuel cell, paramagnetic sensor
Response time < 23 s
Neonatal ow sensor
Flow Range 0.2 to 30 L/min
Dead space <0.75 mL
Resistance 0.9 cmH2
O@10L/min
SideStream CO2
Module
Displayed numeric EtCO2
EtCO2
measurement range 0 to 152 mmHg
Resolution 1 mmHg
Waveforms CO2
-time
Sampling rate Adult/Pediatric: 120 mL/min
Neonate: 90 mL/min
System response time Using Adult/ Pediatric water trap, Adult/Pediatric
sampling line: <5.5 s @ 120 mL/min
Using Neonatal water trap, Neonatal sampling
line:<4.5 s @ 90 mL/min
Rise time Adult/Pediatric water trap,
sampling line: <300 ms @120 mL/min
Neonatal water trap,
sampling line: <330 ms @90 mL/min
Water trap cleaning time Adult/Pediatric water trap: ≥26 h @120 mL/min
Neonatal water trap: ≥35 h @90 mL/min
EtCO2
High alarm limits 2 to 152 mmHg
EtCO2
Low alarm limits 0 to 150 mmHg
MainStream CO2
Module
Displayed numerics EtCO₂, VeCO2
, ViCO2
, MVCO2
, Vtalv, MValv,
VDaw, VDaw/TVe, SlopeCO2
, VDalv, VDphy,
VDphy/TVe, OI, P/F, VCO2
,
EtCO2
measurement range 0 to 150 mmHg
Resolution 1 mmHg
Waveforms / Loop CO2
– time, Volume – CO2
System response time < 2.0 s
EtCO2
High alarm limits 2 to 150 mmHg
EtCO2
Low alarm limits 0 to 148 mmHg
SpO2 module
Displayed numeric SpO2
, PR, PI
SpO2 measurement range 0 to 100 %
PR measurement range 20 to 300 1/min
PI measurement range 0.05 to 20 %
Waveform Pleth
SpO2 High alarm limits 2 to 100 %
SpO2 Low alarm limits 0 to 98 %
SpO2
Desat alarm limits 0 to 98 %
PR High alarm limits 17 to 300 1/min
PR Low alarm limits 15 to 298 1/min
Operation Data
Environmental specifications
Temperature 10 to 40°C(operating); -20 to 60°C(storage)
Relative Humidity 10 to 95 % (operating); 10 to 95 % (storage)
Barometric Pressure 50 to 106 kPa (operating); 50 to 106 kPa
(storage)
Gas supply
Gas type O2
and Air
Pipe Connector NIST, DISS
Gas supply pressure 0.28 to 0.65MPa
Peak flow in case of single supply gas
≥ 180 L/min (BTPS)*
Loss of gas supply In the event of a gas supply failure,
automatically switches over to the other gas
supply available, so that the patient gets the
preset volume and pressure
Backup air supply (Blower)
Maximum output flow ≥ 200 L/min (BTPS)*
Maximum output pressure ≥ 80 cmH2O
Power and Battery Backup
Power input voltage 100 to 240 V
Power input frequency 50/60 Hz
Power input current 2.8 to 1.2 A
Fuse 220V/5.0A
Number of batteries One or Two
Battery type Build-in Lithium-ion battery, 11.3 VDC,
5600 mAh
Battery run time 90 min (Powered by one new fully-charged
battery in standard working condition)*
180 min (Powered by two new fully-charged
battery in standard working condition)
Special Functions and procedures
100% O2
Suction
Nebulization
Manual breath
Inspiratory hold
Expiratory hold
PEEPi
P0.1
NIF
PV-Tool
Weaning Tool
Lung Recruitment Tool (SI)
Alveolus ventilation calculation
Auxiliary Pressure measurement
* BTPS =Body Temperature and Pressure Saturated
* The standard work condition is: Ventilation mode:V-A/C ; TV:500 mL; f:10
/min; Tinsp:2 s ; O2
%:40 Vol.%; 2 2
PEEP:3 cmH2
O ; R:5 cmH2
O/L/s ; C:50 mL/cmH2
O ; Gas supply: O2
and Air
Pipeline gas supply, nominal work pressure: 400±100 kPa.

0.00

Description

Technical Specification
Physical Specification
Dimensions and weight
Dimensions (HxWxD) 1425mmX530mmX647mm
(Including the trolley,including backup air supply)
936mmX473mmX298mm
(Excluding the trolley,including backup air supply))
681mmX473mmX298mm
(Excluding the trolley,excluding backup air supply)
Weight Approximately 48kg
(including the trolley,including backup air supply)
Display
Screen 18.5” Color active matrix TFT touch screen
Display Resolution (H)x(V)1920X1080 pixels
Brightness Adjustable
Trolley
Dimensions 760mm(depth)X530mm(width)X980mm(height)
Weight 17 kg
Communication interface
Communication interface RS-232, Nurse call connector, VGA connector,
USB PortX4, Ethernet
Ventilation Specifications
Patient Type Adult, Pediatric, Neonate
Ventilation Mode V-A/C (Volume assist/control)
P-A/C (Pressure assist/control)
V-SIMV (Volume-Synchronized Intermittent
Mandatory Ventilation)
P-SIMV (Pressure-Synchronized Intermittent
Mandatory Ventilation)
Duolevel (Duo Level Ventilation)
CPAP (Continuous Positive Airway Pressure)
PSV (Pressure Support Ventilation)
VS (Volume Support)
APRV (Airway Pressure Release Ventilation)
PRVC (Pressure Regulated Volume Control)
PRVC-SIMV (PRVC-Synchronized Intermittent
Mandatory Ventilation)
AMV (Adaptive Minute Ventilation)
CPRV (Cardio-Pulmonary Resuscitation
Ventilation)
PSV-S/T(Pressure Support
Ventilation-Spontaneous/Timed)
nCPAP(Nasal Continuous Positive Airway Pressure
ventilation)
Controlled Parameters
O2
% 21 to 100 vol.%
TV (Tidal Volume) Adult: 100 to 4000 mL
Pediatric: 20 to 300 mL
Neonate: 2 to 100 mL
MV% 25% to 350%
f (Ventilation frequency) Adult / Pediatric: 1 to 100 /min
Neonate: 1 to 150 /min
fsimv (Ventilation frequency in SIMV mode)
1 to 60 /min
I:E 1:10 to 4:1
Tinsp (Inspiratory time) 0.10 to 10.00 s
Tslope (Time of pressure rising)
0.00 to 2.00 s
Thigh 0.10 to 30.00 s
Tlow 0.20 to 30.00 s
Tpause OFF, 5% to 60%
Flow Adult: 6 to 180 L/min
Pediatric: 6 to 30 L/min
Neonate: 2 to 30 L/min
∆Pinsp 1 to 100 cmH2O
∆Psupp 0 to 100 cmH2O
Phigh 0 to 100 cmH2O
Plow 0 to 50 cmH2O
PEEP 0 to 50 cmH2O
Flow trigger OFF,
Adult/Pediatric: 0.5 to 20.0 L/min;
Neonate: 0.1 to 5.0 L/min
Pressure trigger OFF, -20.0 to -0.5 cmH2O
Exp% (Expiration termination level)
Auto, 5% to 85%
Base flow Automatic adjustment (3-40L/min in invasive
mode, 10-65L/min in non-invasive mode)
Neg.Plimit (in CPRV mode) -30 to 0 cmH2O
Apnea Ventilation
TVapnea Adult: 100 to 4000 mL
Pediatric: 20 to 300 mL
Neonate: 2 to 100 mL
∆Papnea 1 to 100 cmH2O
fapnea Adult / Pediatric: 1 to 100 bpm
Neonate: 1 to 150 bpm
Apnea Tinsp 0.10 to 10.00 s
Sigh
Sigh Switch ON, OFF
Interval 20 s to 180 min
Cycles Sigh 1 to 20
∆int. PEEP OFF, 1 to 40 cmH2O
Automatic Tube Resistance Compensation
Tube Type ET Tube, Trach Tube, Disable ATRC
Tube I.D. Adult: 5.0 to 12.0 mm
Pediatric: 2.5 to 8.0 mm
Neonate: 2.5 to 5.0 mm
Compensate 1 to 100 %
Expiration Compensation Switch
ON, Off
O2
Therapy
O2
% 21 to 100 vol.%
Flow Adult: 2 to 60 L/min
Pediatric: 2 to 25 L/min
Leakage Compensation
Maximum leakage compensation flow
Adult: 65L/min
Pediatric: 45L/min
Neonate: 15L/min
Monitored parameters
Airway pressure range Ppeak, Pplat, Pmean,
(Range -20 to 120 cmH₂O)
PEEP (Range 0 to 120 cmH₂O)
Tidal volume range TVi, TVe, TVe spn,(Range 0 to 6000 mL)
Frequency range ftotal, fmand, fspn, (Range 0 to 200 /min)
Minute volume range MVi, MVe, MVspn, MVleak,
(Range
Adult/Pediatric: 0 to 100 L/min
Neonate: 0 to 30 L/min)
Leak% 0 to 100%
Resistance Rinsp, Rexp, (Range 0 to 600 cmH₂O/L/s)
Compliance Cstat, Cdyn, (Range 0 to 300 mL/cmH₂O)
Inspired Oxygen (FiO2
) 15 to 100 vol.%
RSBI 0 to 9999 1/(min*L)
WOB WOBtot, WOBvent, WOBimp, WOBpat
(Range: 0 to 100 J/min)
P0.1 -20 to 0 cmH₂O
NIF -45 to 0 cmH₂O
PEEPi 0 to 120 cmH₂O
Vtrap 0 to 4000 mL
RCexp 0 to 10 s
TVe/IBW 0 to 50 mL/kg
I:E 150:1 to1:150
Tinsp 0.00 to 60.00s
PIF (peak inspiratory flow) Adult/Pediatric: 0 to 300 L/min
Neonate: 0 to 30 L/min
PEF (peak expiratory flow)Adult/Pediatric: 0 to 180 L/min
Neonate: 0 to 30 L/min
EEF (end expiratory flow) Adult/Pediatric: 0 to 180 L/min
Neonate: 0 to 30 L/min
C20/C 0.00 to 5.00
Waveforms Airway pressure-time, Flow-time, Volume-
time, CO2
-time , Pleth-time
Loops Paw-Volume, Flow-Volume, Paw-Flow,
Volume-CO2
Alarm settings
Tidal Volume High Neo: Off, 3 to 200 mL
Ped: Off, 25 to 600 mL
Adu: Off,110 to 6000 mL
Low Neo: Off, 1 to 195 mL
Ped: Off, 10 to 595 mL
Adu: Off, 50 to 5995 mL
Minute Volume High Neo: 0.02 to 30.0 L/min
(can be set to Off in nCPAP)
Ped: 0.2 to 60.0 L/min
Adu: 0.2 to 100.0 L/min
Low Neo: 0.01 to 15 L/min
Ped: 0.1 to 30.0 L/min
Adu: 0.1 to 50.0 L/min
(can be set to Off in NIV)
Airway pressure High 10 to 105 cmH2O
Low OFF, 1 to 100 cmH2O
Frequency High OFF, 2 to 160 /min
Low OFF, 1 to 159 /min
Inspired Oxygen (FiO2
) High FiO2
exceeds the alarm limit for at least
30 s, internal alarm limit: set value+max
(7 vol.% or set value X10% ) or 100 vol.%,
whichever is lower.
Low FiO2
lower than the alarm limit for at
least 30 s, internal alarm limit: set
value-max (7 vol.% or set valueX10%) or
18%, whichever is greater.
Apnea alarm time Low 5 to 60 s (can be set to Off in nCPAP)
Other Alarms Low battery voltage
Gas supply pressure low
Airway obstruction
Tube disconnected
PEEP too high
Trend
Type Tabular, Graphic
Length 96 hours
Content Monitor Parameters, Setting Parameters
(Setting Ventilation mode and Parameters)
Log
Type Alarm, Operation
Max number 5000
Screen Capture
Max number 20 pictures
Ventilator components
O2
sensor
Type Calvanic fuel cell, paramagnetic sensor
Response time < 23 s
Neonatal ow sensor
Flow Range 0.2 to 30 L/min
Dead space <0.75 mL
Resistance 0.9 cmH2
O@10L/min
SideStream CO2
Module
Displayed numeric EtCO2
EtCO2
measurement range 0 to 152 mmHg
Resolution 1 mmHg
Waveforms CO2
-time
Sampling rate Adult/Pediatric: 120 mL/min
Neonate: 90 mL/min
System response time Using Adult/ Pediatric water trap, Adult/Pediatric
sampling line: <5.5 s @ 120 mL/min
Using Neonatal water trap, Neonatal sampling
line:<4.5 s @ 90 mL/min
Rise time Adult/Pediatric water trap,
sampling line: <300 ms @120 mL/min
Neonatal water trap,
sampling line: <330 ms @90 mL/min
Water trap cleaning time Adult/Pediatric water trap: ≥26 h @120 mL/min
Neonatal water trap: ≥35 h @90 mL/min
EtCO2
High alarm limits 2 to 152 mmHg
EtCO2
Low alarm limits 0 to 150 mmHg
MainStream CO2
Module
Displayed numerics EtCO₂, VeCO2
, ViCO2
, MVCO2
, Vtalv, MValv,
VDaw, VDaw/TVe, SlopeCO2
, VDalv, VDphy,
VDphy/TVe, OI, P/F, VCO2
,
EtCO2
measurement range 0 to 150 mmHg
Resolution 1 mmHg
Waveforms / Loop CO2
– time, Volume – CO2
System response time < 2.0 s
EtCO2
High alarm limits 2 to 150 mmHg
EtCO2
Low alarm limits 0 to 148 mmHg
SpO2 module
Displayed numeric SpO2
, PR, PI
SpO2 measurement range 0 to 100 %
PR measurement range 20 to 300 1/min
PI measurement range 0.05 to 20 %
Waveform Pleth
SpO2 High alarm limits 2 to 100 %
SpO2 Low alarm limits 0 to 98 %
SpO2
Desat alarm limits 0 to 98 %
PR High alarm limits 17 to 300 1/min
PR Low alarm limits 15 to 298 1/min
Operation Data
Environmental specifications
Temperature 10 to 40°C(operating); -20 to 60°C(storage)
Relative Humidity 10 to 95 % (operating); 10 to 95 % (storage)
Barometric Pressure 50 to 106 kPa (operating); 50 to 106 kPa
(storage)
Gas supply
Gas type O2
and Air
Pipe Connector NIST, DISS
Gas supply pressure 0.28 to 0.65MPa
Peak flow in case of single supply gas
≥ 180 L/min (BTPS)*
Loss of gas supply In the event of a gas supply failure,
automatically switches over to the other gas
supply available, so that the patient gets the
preset volume and pressure
Backup air supply (Blower)
Maximum output flow ≥ 200 L/min (BTPS)*
Maximum output pressure ≥ 80 cmH2O
Power and Battery Backup
Power input voltage 100 to 240 V
Power input frequency 50/60 Hz
Power input current 2.8 to 1.2 A
Fuse 220V/5.0A
Number of batteries One or Two
Battery type Build-in Lithium-ion battery, 11.3 VDC,
5600 mAh
Battery run time 90 min (Powered by one new fully-charged
battery in standard working condition)*
180 min (Powered by two new fully-charged
battery in standard working condition)
Special Functions and procedures
100% O2
Suction
Nebulization
Manual breath
Inspiratory hold
Expiratory hold
PEEPi
P0.1
NIF
PV-Tool
Weaning Tool
Lung Recruitment Tool (SI)
Alveolus ventilation calculation
Auxiliary Pressure measurement
* BTPS =Body Temperature and Pressure Saturated
* The standard work condition is: Ventilation mode:V-A/C ; TV:500 mL; f:10
/min; Tinsp:2 s ; O2
%:40 Vol.%; 2 2
PEEP:3 cmH2
O ; R:5 cmH2
O/L/s ; C:50 mL/cmH2
O ; Gas supply: O2
and Air
Pipeline gas supply, nominal work pressure: 400±100 kPa.

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.